the electrode material
|
rectangular electrode - platinum metal
|
the electrode pressure
|
1.0 ± 0.05N
|
the distance between electrodes
|
4.0mm ± 0.01mm, angle 60 ° ± 5
|
the electrode voltage
|
100 ~ 600V (48 ~ 60HZ) adjustable short-circuit current 1.0 ± 0.1A, voltage drop is less than 10%
|
drops of liquid height
|
30 ~ 40mm adjustable
|
the size of the drops
|
44 to 55 drops / 1cm3 Adjustable
|
drops Time
|
30s ± 5s,
|
the number of drops
|
0 to 9999 times adjustable
|
the leakage judge
|
loop current greater than 0.5A and maintain the 2 seconds the relay to cut off the current, indicating that the sample failed
|
the test process
|
automatic control of test procedures, independent ventilation
|
reference standards
|
IEC60112-2003, GB/T4207-2003, GB4706.1-2005
|
the studio volume
|
0.5 cubic
|
the device outer dimensions
|
1000mm wide x 650mm deep x 1300mm high
|