IEC61032 Jointed Test Finger Probe with 10N
Force Level: 10N
1, According to : IEC 61032:1997 / IEC 60529:2001/IEC60950/ IEC60335/IEC60529/ IEC60045/ IEC60884/IEC60745 and UL
2. The Standard Test Knurled Finger Probe is the necessary appliance to prevent electric shock for household and similar electrical problem.
Technical Parameters:
Knurled Finger Diameter: 12 mm
Knurled Finger Length: 80 mm
Application:
1. The joint part of The Standard Test Knurled Finger Probe can't touch the live parts or close to the dangerous parts, and 50 mm to 20 mm baffle plate cannot enter.
2. In the prevent electric shock test, wirings , power devices, and lighting devices are needed.
Notes:
Both joints shall permit movement in the same plane and the same direction through an angle of 90o with a 0o to +10o tolerance.
|