Daisy10 Multi-parameter Meteorological Weather Monitoring Station
1. Application:
Daisy10 multi-parameter meteorological monitoring station is a multi-element automatic observation station. It can monitor conventional meteorological elements such as temperature, humidity, air pressure, wind direction, wind speed, soil temperature and humidity, and is widely used in meteorology, environmental protection, airports, agriculture and forestry, hydrology, military, storage, scientific research and other fields.
1) A variety of parameters are measured in one, the optional parameters include: air temperature, air humidity, dew point, atmospheric pressure, light intensity, carbon dioxide, soil moisture, soil temperature, soil conductivity, soil PH value, and leaf temperature, leaf humidity, Wind speed, wind direction, solar radiation, etc.
2) The sensor has high accuracy, fast response, good interchangeability and reliable performance.
3) DC wide range power supply, RS485 interface, standard Modbus protocol
4) Multi-parameter integration, easy for system integration.
5) Perfect protection circuit.
2. Technical parameters:
Technical parameters
|
Signal output type
|
RS485 interface
Modbus protocol
|
Supply voltage
|
9-30V / DC DC
|
Preheat time
|
3 minutes
|
Response time
|
30 seconds (90%)
|
Static power
|
20mA @ 24V DC
|
Operating environment
|
Working temperature: -40 ~ 80 ℃
Working humidity: 0 ~ 95% RH (no condensation)
|
Installation method
|
Bracket installation (with bracket mounting plate)
|
Default cable length
|
Power supply and communication cable: 2 meters, cable length can be customized.
|
Connection method
|
Wiring installation
|
Dimensions
|
Diameter * height = 140 * 300mm
|
Air temperature
|
Range: -40 ~ 80 ℃
Accuracy: +/- 0.3 ℃
Resolution: 0.01 ℃
|
Air humidity
|
Range: 0 ~ 100%
Accuracy: +/- 4%
Resolution: 0.01%
|
Dew point
|
Range: -40 ~ 80 ℃
Accuracy: +/- 0.5 ℃
Resolution: 0.01 ℃
|
Air pressure
|
Range: 300 ~ 1100mbar
Accuracy: +/- 1mbar
Resolution: 0.1mbar
|
Illumination
|
Range: 0 ~ 200,000 Lux
Accuracy: +/- 5%
Resolution: 0.1Lux
|
carbon dioxide
|
Range: 0 ~ 5000ppm
Accuracy: +/- (50ppm + 5% reading value)
Resolution: 1ppm
|
Soil temperature
|
Range: -40 ~ 80 ℃
Accuracy: +/- 0.5 ℃
Resolution: 0.01 ℃
|
Soil Moisture
|
Range: 0 ~ 100%
Accuracy: 2% within 0-50%, 3% within 50-100%
Resolution: 0.01%
|
Soil conductivity
|
Range: 0 ~ 20000us / cm
Accuracy is +/- 3% in the range of 0 ~ 10000us / cm; +/- 5% in the range of 10000 ~ 20000us / cm
Resolution: 1us / cm
|
Leaf temperature
|
Range: -40 ~ 80 ℃
Accuracy: +/- 0.5 ℃
Resolution: 0.01 ℃
|
Foliar humidity
|
Range: 0 ~ 100%
Accuracy: +/- 5%
Resolution: 0.01%
|
Soil pH
|
Range: 0 ~ 14PH
Accuracy: +/- 0.1PH
Resolution: 0.01PH
|
3. Dimension:
Diameter: 140mm, height: 300mm
4. Model selection:
Code number
|
code
|
Code description
|
Code 1: Product series
|
Daisy10
|
Daisy10 multi-parameter weather monitoring station
|
Code 2: Supply voltage
|
A
|
9-30V DC
|
Code 3: Output signal
|
A
|
RS485 interface, Modbus protocol
|
Code 4: Communication and power cable length
|
002
XXX
|
2 meters long
Customized, XXX is any line length (unit: m)
|
Code 5: Installation method
|
A
X
|
Bracket installation
This item is not needed
|
Code 6: Air temperature
|
A
X
|
Range: -40 ~ 80 ℃
This item is not needed
|
Code 7: Air humidity
|
A
X
|
Range: 0 ~ 100%
This item is not needed
|
Code 8: Dew point
|
A
X
|
Range: -40 ~ 80 ℃
This item is not needed
|
Code 9: Atmospheric pressure
|
A
X
|
Range: 300 ~ 1100mbar
This item is not needed
|
Code 10: Illumination
|
A
X
|
Range: 0 ~ 200,000 Lux
This item is not needed
|
Code 11: Carbon dioxide
|
A
B
C
D
E
F
X
|
Range: 0-1000ppm
Range: 0-2000ppm
Range: 0-5000ppm
Range: 0-10000ppm
Range: 0-30000ppm
Range: 0-50000ppm
This item is not needed
|
Code 12: Soil temperature
|
A
X
Z
|
Range: -40 ~ 80 ℃
This item is not needed
Customized (parameters such as cable length)
|
(Default 2 meters long)
|
A
X
Z
|
Range: 0 ~ 100%
This item is not needed
Customized (parameters such as cable length)
|
Code 13: Soil moisture
|
A
X
Z
|
Range: 0 ~ 20000us / cm
This item is not needed
Customized (parameters such as cable length)
|
(Default 2 meters long)
|
A
X
Z
|
Range: -40 ~ 80 ℃
This item is not needed
Customized (parameters such as cable length)
|
Code 14: Soil conductivity
|
A
X
Z
|
Range: 0 ~ 100%
This item is not needed
Customized (parameters such as cable length)
|
(Default 2 meters long)
|
A
X
Z
|
Range: 0 ~ 14PH
This item is not needed
Customized (parameters such as cable length)
|
Model example:
Daisy10 multi-parameter weather monitoring station, 9-30V DC power supply, RS485 interface, Modbus protocol, power supply and communication cable 2 meters, bracket installation, air temperature, air humidity, dew point, atmospheric pressure measurement The selection code is: Daisy10-AA002AAAAAXXXXXXXX
|
|