中文版 English
 
Hot news:
  Products
IEC Test Finger Probe
IPX1-IPX9K Waterproof Test Equipment
Electrical Appliance Testing Equipment
Environmental Test Chamber
Battery test equipment
Textile Test Equipment
Mechanical testing machine
Plug and socket testing equipment
test package
Laser Power Senser Measurement
Soil Sensor
Hot Product
IPX1 IPX2 Drip Waterproof Test...
UL1439 Sharp Edge Tester
BND-TPK05 IEC 60529 Test Probe...
IEC62368 test probe kit BND-TP...
IEC 61032 Standard Test Probe ...
IEC60320 EN60320 Appliances co...
UL 498 Standard Plugs and Rece...
IPX1 to IPX4 Drip rain test an...
Vertical horizontal vibration ...
IP5X IP6X Sand and dust proof ...
climate constant temperature a...
IPX1 to IPX9 waterproof testin...
 
 
Products
IEC 61591 2014 Range Hood Air Performance Air Volume Testing System
Name:IEC 61591 2014 Range Hood Air Performance Air Volume Testing System
Type:BND-61591
Manufacturer:IEC 61591: 2014 kitchen Hood Air Performance (Air Volume) Testing System For Pressure Efficiency Test,The test system can measure and draw the corresponding curves of static pressure and air volume, air volume and speed, current, power, efficiency, etc.
Product Description:

Product Overview

Product Name: IEC 61591 Range Hood/kitchen hood/ exhaust hood Air Volume Measurement Test system

Model Specification: BND-61591

Our air volume measurement test system is meticulously crafted to meet international standards such as IEC61591, EN61591, GB/T1236, and GB/T14806. This device is essential for accurately measuring the air volume of cooling fans, axial flow fans, ventilation fans, range hoods, and air blowers.


Specifications

Standard Compliance:

  • IEC61591
  • EN61591
  • GB/T1236
  • GB/T14806

Key Features:

1. Multi-Nozzle Wind Chamber Structure: Select the corresponding nozzle based on the measured flow rate to cover a wide range of flow rates.
2. Dual Functionality: Suitable for both air outlet and air intake tests.
3. Auxiliary Fan: Measure full-range performance curves with zero flow and zero static pressure.
4. Automatic Testing: Computerized automatic testing, calculation, and data output with graphical results display.
5. Test Items: Measure P-Q characteristics (flow rate vs. static pressure), Q-η characteristics (flow rate vs. efficiency), fluid dynamic efficiency (FDEhood), speed, current, and power.


Performance and Characteristics:

*High accuracy and reproducibility
*Easy operation with human-computer dialogue interface
*Time-efficient testing process (only ten minutes per test)

Applications

Our Air Volume Measurement Test Device is ideal for:

  • Cooling Fans
  • Axial Flow Fans
  • Ventilation Fans
  • Range Hoods/kitchen hood/exhaust hood
  • Air Blowers

This kitchen hood Air Performance Air Volume Testing System meets the rigorous requirements needed for scientific research and production processes in various industries.


How It Works

The basic principle of our air volume measurement test device involves simulating the actual working state of the test product in a wind tunnel. The auxiliary fan ensures that the test product's outlet pressure meets the required conditions. By measuring the air pressure difference on both sides of the nozzle in the wind tunnel, we can calculate the corresponding wind speed using standard formulas. Finally, by multiplying the nozzle area by the relevant flow coefficient, we obtain the air volume.


Technical Parameters:


Item Unit Scope Accuracy Other
Air volume (flow rate) m³/min 0~50 ±2%
Static pressure/differential pressure


Pa


0~2000

Full scale ±0.055% Response time does not exceed 90ms


Voltage


V


0~300V

±(0.15% of reading + 0.35% of range) 10Hz≤f<440Hz


Current


A

0~5mA 0~20A ±(0.15% of reading + 0.35% of range) 10Hz≤f<440Hz
Power W 0~5000W

±(0.15% of reading + 0.50% of range)

±(0.25% of reading + 0.50% of range)

10Hz≤f<45Hz


45Hz≤f<440Hz


Temperature


°C


-20~80

±0.2°C

With a temperature gauge with a display accuracy of at least 0.1°C
Humidity % 0~100 ±3%RH Humidity meter with 0.1%RH
Atmospheric pressure kPa 0-200 ≦±200Pa Barometric pressure sensor
Speed (standard configuration)


RPM


0-5000


±5 RPM

Measuring distance 5~100 cm



1. Measuring Air Volume Range: (0.2 m³~50 m³)/min ±1%
2. Static Pressure: 0~1250Pa ±0.2%
3. Differential Pressure: 0~1250Pa ±0.2%
4. Speed: 0~5000 rpm ±0.5%
5. Air Temperature: 0~50℃ ±0.5℃
6. Air Humidity: (5~99)%R﹒ H ±5%
7. Atmospheric Pressure: 94000~106000 Pa ±200 Pa

8. Sample Power Supply Electrical Parameters:

Voltage AC 0~300V ±0.5%
·Current AC 0~5A ±0.5%
·Power 0~1000W ±0.5%

9. Sample Power Supply Variable Frequency Regulated Power Supply:

Input Voltage: AC 220V 50HZ
·Output Voltage: AC 0-110V-220V-300V continuously adjustable,
·Output Frequency: 50HZ or 60HZ
·Output Power: 0-1000W
10. Laboratory Power Supply: AC 380V, 50HZ; Maximum power: 5KVA; Ground wire must be grounded.

11. Laboratory Environment:

Temperature: 20℃±5℃
·Humidity: 30%--80%
·Atmospheric Pressure: Normal

·After completing a test, our software automatically calculates:

Maximum Static Pressure (Pa(max) Pa)
·Maximum Air Volume (Q(max) m3/min)
·Static Pressure at Specified Air Volume (7m3/min) Pa(7m3/min) Pa
·Main Motor Input Power at Specified Air Volume (7m3/min): P W
·Total Pressure Efficiency at Specified Air Volume (7m3/min): η %
·Fluid Dynamic Efficiency: FDEhood %
·Optimal Efficiency Metrics: Air Volume Q, Static Pressure Pa, Power W
·Impeller Speed at Maximum Air Volume: RPM
·Characteristic Curves for Static Pressure Pa and Air Volume Q at various pressures (e.g., 5 Pa, 15Pa, 30Pa)

Test Software

1. Uses WinXP operating system with a window interface and Chinese display.
2. Collects all measured data in real-time as numbers and tables.
3. Automatically analyzes original data after tests are completed.
4. Provides historical data query functionality based on test date, number, model, etc.

5. Customizable interface and data per user requirements.


Test principle and layout:


This solution adopts the blowing test mode, and controls the air volume by stepless adjusting the frequency of the auxiliary fan through the frequency converter; the middle of the air chamber is composed of a flow equalizing orifice plates, nozzles, starting actuators and nozzle plates; the chamber interface size is 600mm×600mm. This system automatically calculates the fan air volume by measuring the pressure difference before and after the nozzle. When the equipment is running, the air performance test device is run on, the air volume of the auxiliary fan is controlled by controlling the opening and closing combination of the nozzles and the current frequency of the frequency conversion device. The static pressure under the corresponding air volume is measured by a high precision micromanometer, so as to obtain the corresponding data of the air volume and air pressure of the specimen, and draw the air volume and air pressure curve. The system is compatible with the air performance test of two types of range hoods: external exhaust type A and suction type B.



IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 0

IEC 61591 Cooking Fume Extractor Air Volume Measurement System For Measuring Performance 1




 
Home  |  Products  |  News  |  About us  |  Feedback  |  Contact us  |  
Copyright © 2008-2015 Hong Kong Bonad Technology Limited | Shenzhen Bonad Instrument Co., LTD. All Rights Reserved.
 
    Add:C505, Hongdu Building,Bao\'an45 district,Shenzhen,518101,Guangdong Province,China    Tel:+86-13380391156    Fax:0755-23721200    Email:Alice@szbonad.com